Product overview fm200 fire suppression system clean agent power protects people and property n nonconductive and will not shortout electronic equipment or thermally shock detects fire in early stages n suppresses class a, b and c fires n less visual obscuration and minimal risk to personnel n colorless, odorless clean agent leaves no residue n electrically nonconductive. Fike corporation halon, fm200fe 227 and highpressure co2, detection and control for the shp, intellescan, cheetah and rhino. Procedure for removing fike gca gas cartridge actuator devices from fike system bottles. Fm 200 1,1,1,2,3,3,3heptafluoropropane, cf3chfcf3 is a colorless odorless gas, low in toxicity, electrically nonconductive, leaves no residue, and is an extremely effective fire suppression agent.
The detection circuits can be configured using cross, counting. And it discharges in 10 seconds or less, extinguishing a fire quickly and. Aug 25, 2000 fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. Fike fm200 fire suppression systems the fm200 fire suppression system is designed to extinguish flammable liquids and electrical fires within 10 seconds.
Fikes hydraulic tubing drain htd disc estimation tool is a webbased application designed for users to calculate the approximate size and model htd disc for use in the oil mining application of the user based solely upon data provided by the user. Ecs clean agent fire suppression systems are the preferred fire suppression solution for facilities that cannot afford the downtime associated with a fire or typical waterbased fire suppression systems. As the fastest waterless fire protection system available, protecting your business with the fm200 system will result in less damage, less need for repairs, and increased safety for your. The fm 200 system is most effective when used with the autopulse detection system to introduce the clean agent rapidly. Sep 18, 2012 fike s clean agent calculator can be accessed and downloaded onto mobile devices, by going to fike is a globally recognized supplier of products and services that protect people and critical assets from dangers such as fire, explosion, and overpressurization.
Ecaro25 requires 20% less agent per cubic foot meter than hfc227ea systems and 38% less clean agent per cubic foot meter than fk5112. In addition, the app provides a sidebyside comparison of fikes premier fire suppression products ecaro25, dupont fm200 and. The flow lab also assists in the development of customengineered solutions for unique client needs. To schedule fm 200 system services in the new jersey or delaware area, contact confires online or call 888 2280917. The benefits of a fm200 fire suppression system fireline. Fm 200 fire suppression systems fm 200 fire suppression system dispenses an agent into the fire. Licensed to youtube by gp records on behalf of gp records. See the capabilities rigorously tests electrical fire and explosion products before being submitted for ulfm approval and ultimately being offered to fike clients. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. Apr 21, 2010 cofessco fire protection has been building longterm relationships with west michigan businesses since 1969 and has become the standard by which other companies are measured. Less clean agent fikes ecaro25 clean agent fire protection system. Even one day lost to firerelated downtime can result in lost revenue, customers, and profits.
This 2day class will cover the application and design of an fm 200 system with an emphasis on nfpa 2001 compliance. Don is responsible for internal training, software development, and support, as well as system design. What is fm200 fire suppression and what are its advantages. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Fike clean agent containers have passed extensive testing by factory mutual and underwriters laboratory and are used in installations where 3 to 1045 pounds 2. The work described in the specification consists of all labor, materials, equipment, and services necessary and required to complete and test the system. A fike hfc227ea clean agent fire suppression system provides an economical, environmentally acceptable solution for your fire protection needs. By installing an fm200 fire suppression system, you are protecting your assets and employees with one of the leading waterless fire protection systems available. Historically, the most widely used halon 1 replacement, fm200 provides waterless fire suppression without leaving behind residue or particulate, and has been installed in over one hundred thousand applications in more than 70 nations. Fires are immediately suppressed by the agent, which otherwise known as hfc227ea. Fm200 fire suppression systems american fire protection. Fike protection systems has conducted extensive testing over the past several years and has developed the necessary knowledge to incorporate fm200 into its fire suppression system product line. Since the fire suppression agent leaves no residue and requires no cleanup, its ideal for use in computer rooms, museums, historical archives, and many other.
Fire suppression systems fike fast solutions for any application. Ecs clean agent fire suppression system kiddefenwal. The fm200 system stops fires fast by deploying quickly to prevent extensive damage, excessive repair costs, and delayed downtime for your business. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection. Buddy has received extensive specialized training and recognition from safe fire detection in the layout, design and installation of air sampling and linear.
Fm200 reacts quickly at low concentrations to eliminate a fire. The clean agent is retained in the container by a impulse valve assembly which contains a fastacting rupture disc. Why just contain a fire when you can extinguish it. Fm200 fm200 is a registered trade mark of the du pont system in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release engineered hydraulic flow program used to predict the two phase flow of fm200 through a pipe network contacts. Fikes hfc227ea also known as fm200, a registered trademark of great. Software development finite element analysis core mathematical model key kidde systems performance data ecsiii version software. Fire suppressants the fire protection modern businesses need. This makes it a suitable choice for new installations using total flooding systems, and for halon 1 replacement applications. Fm200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. The grabcad library offers millions of free cad designs, cad files, and 3d models. In normally occupied areas, people can breathe fm200 at extinguishing concentrations without fear. Fike fm200 clean agent fire suppression system with the shp pro control panel fm200 system w shp pro specification page 2 of 8 pn. Without a fm200 fire suppression system, you risk losing valuable time and business assets if a fire emergency occurs. Fm200 is an odorless, colorless, liquefied compressed gas.
Medical facilitiesups roomstelecommunication facilitiescomms roomsdata centres what advantages are. After receiving the fire signal, fm 200 is discharged totally from the cylinders within 10 seconds to fill up the space uniformly at the design concentration to extinguish the fire. This specification outlines the requirements for a crosszoned detection and total flooding fm200 fire suppression system. This type of fire suppression system is usually used in. This 2day class will cover the application and design of an fm200. The extinguishing performance of fm 200 appears to be not so quick as btm. Fm200 1,1,1,2,3,3,3heptafluoropropane, cf3chfcf3 is a colorless odorless gas, low in toxicity, electrically nonconductive, leaves no residue, and is an extremely effective fire suppression agent. Fike clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. A company with a wide range of certifications is a clear sign of guarantee which entails higher technical level and, above all, greater commitment to product quality. Fireline is here to tell you about the fm 200 fire suppression system and the benefits that come with the installation of an fm 200 fire suppression system. In this 2day course, you will learn how to design, configure, install and maintain a fm 200 hfc227 suppression system. Safe fire protection, a new cost effective, clean, non.
The atmospheric lifetime of fm 200 has been determined to be 36. The fm 200 system stops fires fast by deploying quickly to prevent extensive damage, excessive repair costs, and delayed downtime for your business. Data sheet agent storage containers with hfc227ea description fike clean agent containers are used in fire extinguishing systems to store the clean agent until a fire develops and the agent must be released. Chemours brings a history of leadership in fire protection, making it a driving force in the development of safe, clean alternatives to commonly used fire suppression systems in military applications, cultural property, data centers, and other critical installations.
Fike clean agent containers are used in fire extinguishing systems to store the. Chemours brings a history of leadership in fire protection, making it a driving force in the development of safe, clean alternatives to commonly used fire suppression systems in military applications. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Fm 200 is an odorless, colorless, liquefied compressed gas. The windowsbased user interface provides a convenient, fast, and userfriendly method for entering information about the system. This 2day class will cover the application and design of an fm200 system with an emphasis on nfpa 2001 compliance. To help ensure your fire suppression system remains compliant with the latest regulations, johnson controls is offering a full hydrostatic test service htesting for fm200, sapphire, co2 and inert gas containers that have been in service for 10 years. Fm200 is included in nfpa2001, under the generic name hfc227ea, and has been evaluated and. Cofessco fire protection has been building longterm relationships with west michigan businesses since 1969 and has become the standard by which. The chemical is 1,1,1,2,3,3,3heptafluoropropane or hfc227ea, liquefied compressed gas. Unlike traditional water sprinklers, each of fike s fastacting automatic fire suppression solutions are designed to extinguish fire hazards as quickly as possible, minimizing fire damage, smoke damage and even water damage.
Flow calculation software for engineered suppression systems. Fike s clean agent system with fm 200 also known as hfc227ea, uses fike s patented rupture disc valve design offering additional flexibility, effectiveness and speed. Fm 200 is included in nfpa2001, under the generic name hfc227ea, and has been evaluated and. American fire protection group designs, installs and repairs waterless fm200 fire suppression systems for a variety of highhazard commercial and industrial applications, including data processing centers, process control rooms, clean manufacturing facilities, bank vaults, simulators, battery backup rooms and document storage areas. The remote testing facility also supports fikes product development and use in future applications, among other essential responsibilities. Safe fire protection a leader in special hazard systems. The physical and chemical properties of fm 200 are not the same as btm. Fike protection systems has conducted extensive testing over the past several years and has developed the necessary knowledge to incorporate fm 200 into its fire suppression system product line. Halon 1 btm is an effective fire suppressant and has been widely used in total flooding gas protection system. The superior properties of our unique system allow you to utilize small diameter piping over long distances, making it easier and less expensive to. Fm200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. The material safety data sheet msds covering fm200 should be read and understood prior to working with the agent. Fm 200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes associated with other proposed halon replacements. Join the grabcad community today to gain access and download.
The function of the fike engineered discharge nozzle in a fire extinguishing system. In july of 2009 don joined safe fire protection, inc. A proven, effective and reliable fire suppression option. Fm200 is an important part of an environmentally responsible clean agent fire suppression solution with a zero ozonedepleting potential. In this 2day course, you will learn how to design, configure, install and maintain a fm200hfc227 suppression system. Revised software packages will be available for free download on the fike technical support website. Fike clean agent system flow calculation software hfc227ea. The kidde flow calculation software for engineered suppression systems is a sophisticated calculation routin e for predicting the flow of an agent through a pipe network system. As the fastest waterless fire protection system available, protecting your business with the fm 200 system will result in less damage, less need for repairs, and increased safety for your. Our hydrostatic testing service provides, where possible, a service exchange of. Fm200 suppression systems historically, the most widely used halon 1 replacement, fm200 provides waterless fire suppression without leaving behind residue or particulate, and has been installed in over one hundred thousand applications in more than 70 nations. Fikes clean agent calculator can be accessed and downloaded onto mobile devices, by going to fike is a globally recognized supplier of products and services that protect people and critical assets from dangers such as fire, explosion, and overpressurization. Fike fm 200 fire suppression systems the fm 200 fire suppression system is designed to extinguish flammable liquids and electrical fires within 10 seconds. That translates into minimal equipment facility damage and little or no business interruption.
An overview of fire suppression systems and their applications. Fireline is here to tell you about the fm200 fire suppression system and the benefits that come with the installation of an fm200 fire suppression system. Fm 200 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. By installing an fm 200 fire suppression system, you are protecting your assets and employees with one of the leading waterless fire protection systems available. Fike is a globally recognized supplier of products and services that protect people and critical assets from dangers such as fire, explosion, and overpressurization. Fm200 and ecaro25 software packages have been updated to include the impulse valve equivalent lengths as well as new container part numbers. These 2 day courses each offer 14 professional development hours pdhs.
Fm200 clean agent fire suppression system hfc227 fike. The clean agent fire master 200 fm200, heptafluoropropane is widely used as a substitute for halon. The atmospheric lifetime of fm200 has been determined to be 36. This tool provides only a general estimate of the aforementioned items and does not take into.
Please contact your local fike office or salescustomer service contact if you have concerns. It is a waterless fire protection system thats released into the risk inside a 10 second time frame. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. This detection system is used to actuate a single, fixed fire suppression or alarm system based on inputs received from fire detection devices. Our clean agent fire protection system, using dupont fm200 as thefm200 fe227ea heptafluoropropane cf3chfch3extinguishing agent.
Our local and global teams are doing everything they can to ensure our products arrive as quickly as possible. Students will learn how to use the fike co2 flow calculation software. Fm 200 is an important part of an environmentally responsible clean agent fire suppression solution with a zero ozonedepleting potential. Fm 200 fire suppression system orr protection systems. Fm 200 is a halocarbon agent accepted as an alternative to halon for total flooding fire suppression systems. Jun 27, 2012 without a fm 200 fire suppression system, you risk losing valuable time and business assets if a fire emergency occurs.
Equations for calculating the resulting clean agent concentration were added to nfpa 2001 for the 2015 edition. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. With over 65 years of experience manufacturing safety solutions, fike offers a complete line of proven, reliable products to customers around the world. Often fm200 systems are employed to protect critical installations formerly protected by halon 1. Often fm 200 systems are employed to protect critical installations formerly protected by halon 1. The work described in this specification includes all engineering, labor, materials. Learn how the the fm200 clean agent fire protection system hfc227ea leaves no residue and doesnt require costly cleanup. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. We provide an immediate response to clean agent fire suppression system discharges, whether accidental or from a fire, to get your system back into service as quickly as possible.
828 1605 59 735 394 308 233 1083 784 1585 1545 381 339 1310 1426 1382 1485 566 144 1340 672 144 1536 1312 1121 436 139 1316 1166 88 147 422 471 256 941 915 1614 1477 136 1217 675 698 847 1169